Paddock™ Intelligent Automatic Pump Pressure Controller – 10A, 2.2kW
Description
The Paddock™ Intelligent Pump Pressure Controller provides automatic start and stop control for compatible household and water transfer pumps. Combining pressure and flow sensing with adjustable start pressure, an integrated non-return valve and extended priming protection, it provides convenient on-demand pump operation.
Designed for inline installation on the pump discharge, the controller is rated for loads up to 10A / 2.2kW and features 1" BSP connections and an IP65 enclosure.
Paddock™ Intelligent Automatic Pump Pressure Controller
This automatic pressure controller is designed to start and stop a compatible water pump in response to water demand. When a tap or outlet is opened, the controller can activate the pump; when demand stops, the controller automatically shuts the pump down.
Adjustable pressure settings allow the controller to be configured for different pumping systems, while integrated pressure and flow sensing provides automatic operation without requiring a conventional large pressure tank.
Key Features
- Automatic pump start and stop control
- Suitable for compatible household and water transfer pumps
- 90–265V AC, 50/60Hz
- Maximum current rating: 10A
- Suitable for motors up to 2.2kW within the controller's electrical ratings
- Adjustable 0–10 bar starting pressure
- 15 bar maximum system pressure
- Integrated pressure sensor
- Integrated flow switch
- Built-in non-return valve
- Integrated receiver chamber helps reduce unnecessary cycling
- Extended self-priming timer
- No-flow protection
- Simple + / – pressure adjustment
- 1" BSP inlet and outlet
- IP65 enclosure
- Maximum water temperature: 80°C
- 12 month warranty
Automatic On-Demand Pump Control
The controller monitors the water system and automatically operates the pump as demand changes. When pressure falls and water flow is detected, the controller can start the pump to restore water supply.
When demand stops and the outlet is closed, the controller detects the change in flow and automatically stops the pump.
Adjustable Starting Pressure
The pump starting pressure can be adjusted from 0 to 10 bar using the + and – controls on the front panel. This allows the controller to be configured to suit the requirements of the pump and water system.
The selected settings must remain within the operating limits of the pump, pipework and other components in the system.
Integrated Flow & Pressure Sensing
The controller incorporates both a pressure sensor and flow switch. Using both inputs allows it to respond to changes in system pressure and actual water demand.
An integrated non-return valve helps maintain system pressure and reduce unnecessary pump cycling.
Integrated Receiver Chamber
A small integrated receiver chamber helps reduce unnecessary pump cycling during very low-demand conditions, such as minor leakage or a dripping tap.
This is an integrated controller chamber rather than a replacement for a larger pressure tank where one is required by the specific pumping system.
Extended Self-Priming Timer
When the pump starts, the controller allows approximately 3 minutes 20 seconds for the pump to establish flow before shutting down.
This extended priming period can be useful with installations where the pump requires additional time to prime, including some jet-pump applications.
No-Flow Protection
If water flow is lost while the pump is operating, the controller allows approximately 3 minutes 20 seconds without flow before switching the pump off.
This provides protection where the water supply is interrupted or the pump is unable to establish normal flow.
IP65 Construction
The controller has an IP65 enclosure rating, with the electronic PCB encapsulated in epoxy resin for additional protection.
Installation should still be carried out in accordance with the controller's requirements, with electrical connections and associated equipment appropriately protected for the installation environment.
Specifications
| Specification | Details |
|---|---|
| Supply Voltage | 90–265V AC |
| Frequency | 50/60Hz |
| Maximum Current | 10A |
| Maximum Motor Rating | Up to 2.2kW within controller electrical limits |
| Adjustable Starting Pressure | 0–10 bar |
| Maximum System Pressure | 15 bar |
| Maximum Water Temperature | 80°C |
| Inlet / Outlet | 1" (25mm) BSP |
| Operation | Automatic / adjustable |
| Pressure Sensor | Integrated |
| Flow Switch | Integrated |
| Non-Return Valve | Integrated |
| Receiver Chamber | Integrated |
| Self-Priming Timer | Approx. 3 minutes 20 seconds |
| No-Flow Shut-Off Delay | Approx. 3 minutes 20 seconds |
| Ingress Protection | IP65 |
| Weight | Approx. 1kg |
| Warranty | 12 months |
Installation & Compatibility
The controller is installed inline on the discharge side of the pump. Ensure the pump, controller, pipework and connected equipment are suitable for the selected operating pressure and application.
Where the controller and pump are supplied with compatible plug-and-play electrical connections, installation can be simplified. Any fixed wiring, electrical modification or installation requiring electrical work must be completed in accordance with applicable electrical requirements.
Important: Confirm that the pump's voltage, motor power and maximum current draw are within the controller's ratings before installation. The controller is rated to a maximum of 10A.